BMC CONTROL-O configuration/parameter values are not specified properly.
Severity | Group ID | Group Title | Version | Rule ID | Date | STIG Version |
---|---|---|---|---|---|---|
medium | V-224589 | SRG-OS-000018 | ZCTO0040 | SV-224589r1070214_rule | 2025-02-24 | 7 |
Description |
---|
BMC CONTROL-O configuration/parameters control the security and operational characteristics of products. If these parameter values are improperly specified, security and operational controls may be weakened. This exposure may threaten the availability of the product applications, and compromise the confidentiality of customer data. |
ℹ️ Check |
---|
Refer to the following applicable reports produced by the z/OS Data Collection: - IOA.RPT(SECPARM) Automated Analysis Refer to the following report produced by the z/OS Data Collection: - PDI(ZCTO0040) The following keywords will have the specified values in the BMC CONTROL-O security parameter member: Keyword Value DEFMCHKO $$CTOEDM SECTOLO NO DFMO01 EXTEND DFMO02 EXTEND DFMO03 EXTEND DFMO04 EXTEND DFMO08 EXTEND DFMO10 PROD (new for 6.3.xx) DFMO15 EXTEND |
✔️ Fix |
---|
The BMC CONTROL-O Systems programmer will verify that any configuration/parameters that are required to control the security of the product are properly configured and syntactically correct. Set the standard values for the BMC CONTROL-O security parameters for the specific Access Control Program (ACP) environment along with additional IOA security parameters with standard values as documented below. Keyword Value DEFMCHKO $$CTOEDM SECTOLO NO DFMO01 EXTEND DFMO02 EXTEND DFMO03 EXTEND DFMO04 EXTEND DFMO08 EXTEND DFMO10 PROD (new for 6.3.xx) DFMO15 EXTEND |