The Samsung SDS EMM must enforce the limit of three consecutive invalid logon attempts by a user.

Severity
Group ID
Group Title
Version
Rule ID
Date
STIG Version
mediumV-225656PP-MDM-991000SSDS-00-200250SV-225656r588007_rule2022-06-101
Description
By limiting the number of failed login attempts, the risk of unauthorized system access via user password guessing, otherwise known as brute forcing, is reduced. Limits are imposed by locking the account. SFR ID: FMT_SMF.1(2)b. / IA-7-a Satisfies: SRG-APP-000065, PP-MDM-991000
ℹ️ Check
Review the Samsung SDS EMM configuration settings and verify the server is configured to enforce the limit of three consecutive invalid logon attempts by admin. On the MDM console, verify that the MDM console "Maximum Failed Login Attempts" is set to "3". If the administrator incorrectly enters the login password three times, the account is locked. If the MDM console Maximum Failed Login Attempts is not set to "3", this is a finding.
✔️ Fix
Configure the Samsung SDS EMM to enforce the limit of three consecutive invalid logon attempts by an admin. On the MDM console, do the following: 1. Log in to the Admin Console using a web browser. 2. Go to Setting >> Server >> Configuration and set "Maximum Failed Login Attempts" to "3".