The Juniper SRX Services Gateway must be configured to synchronize internal information system clocks with the primary and secondary NTP servers for the network.
Severity | Group ID | Group Title | Version | Rule ID | Date | STIG Version |
---|---|---|---|---|---|---|
medium | V-223205 | SRG-APP-000373-NDM-000298 | JUSX-DM-000094 | SV-223205r1015751_rule | 2024-12-20 | 3 |
Description |
---|
The loss of connectivity to a particular authoritative time source will result in the loss of time synchronization (free-run mode) and increasingly inaccurate time stamps on log events and other functions. Multiple time sources provide redundancy by including a secondary source. Time synchronization is usually a hierarchy; clients synchronize time to a local source while that source synchronizes its time to a more accurate source. The network device must utilize an authoritative time server and/or be configured to use redundant authoritative time sources. |
ℹ️ Check |
---|
Verify the Juniper SRX is configured to synchronize internal information system clocks with the primary and secondary NTP sources. [edit] show system ntp If the Juniper SRX is not configured to synchronize internal information system clocks with an NTP server, this is a finding. |
✔️ Fix |
---|
The following commands allow the device to keep time synchronized with the network. To designate a primary NTP server, add the “prefer” keyword to the server statement. [edit] set system ntp server <NTP-server1-IP> prefer set system ntp source-address <MGT-IP-Address> set system ntp server <NTP-server2-IP> set system ntp source-address <MGT-IP-Address> |