The HP FlexFabric Switch must generate an immediate real-time alert of all audit failure events requiring real-time alerts.

Severity
Group ID
Group Title
Version
Rule ID
Date
STIG Version
mediumV-66245SRG-APP-000360-NDM-000295HFFS-ND-000097SV-80735r1_rule2020-06-031
Description
It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required. Without a real-time alert, security personnel may be unaware of an impending failure of the audit capability and system operation may be adversely affected. Alerts provide organizations with urgent messages. Real-time alerts provide these messages immediately (i.e., the time from event detection to alert occurs in seconds or less).
ℹ️ Check
Determine if the HP FlexFabric Switch provides the capability for organization-identified individuals or roles to change the auditing to be performed based on all selectable event criteria within near-real-time. [HP] display info-center Information Center: Enabled Console: Enabled Monitor: Enabled Log host: Enabled 192.100.50.27, port number: 514, host facility: local7 Log buffer: Enabled Max buffer size 1024, current buffer size 512 Current messages 66, dropped messages 0, overwritten messages 0 Log file: Enabled Security log file: Enabled Information timestamp format: Log host: Date Other output destination: Date If the HP FlexFabric Switch does not provide the capability for organization-identified individuals or roles to change the auditing to be performed based on all selectable event criteria within near-real-time, this is a finding.
✔️ Fix
Configure the HP FlexFabric Switch to generate an immediate real-time alert of all audit failure events requiring real-time alerts. [HP] info-center enable