Forescout must generate a log record when the client machine fails policy assessment because required security software is missing or has been deleted. This is required for compliance with C2C Step 1.

Severity
Group ID
Group Title
Version
Rule ID
Date
STIG Version
mediumV-233335SRG-NET-000492-NAC-002110FORE-NC-000340SV-233335r811420_rule2024-12-192
Description
Generating log records with regard to modules and policies is an important part of maintaining proper cyber hygiene. Keeping and maintaining the logs helps to establish, correlate, and investigate the events relating to an incident, or identify those responsible for one.
ℹ️ Check
If DoD is not at C2C Step 1 or higher, this is not a finding. Use the Forescout Administrator UI to verify a central log server's IP address is configured withing the Syslog configuration settings. 1. Log on to the Forescout UI. 2. Select Tools >> Option >> HPS Inspection Engine >> SecureConnector. 3. In the Client-Server Connection, check the Minimum Supported TLS Version is set to TLS version 1.2. If the NAC does not use TLS 1.2, at a minimum, to protect the confidentiality of information passed between the endpoint agent and the NAC for the purposes of client posture assessment, this is a finding.
✔️ Fix
Use the Forescout Administrator UI to configure a Syslog server. Log on to the Forescout UI. 1. Select Tools >> Option >> HPS Inspection Engine >> SecureConnector. 2. In the Client-Server Connection, set the Minimum Supported TLS Version to TLS version 1.2.