The F5 BIG-IP appliance must record time stamps for audit records that can be mapped to Coordinated Universal Time (UTC).

Severity
Group ID
Group Title
Version
Rule ID
Date
STIG Version
mediumV-266077SRG-APP-000374-NDM-000299F5BI-DM-300037SV-266077r1024609_rule2024-09-201
Description
If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analysis. Time stamps generated by the application include date and time. Time is commonly expressed in UTC, a modern continuation of Greenwich Mean Time (GMT), or local time with an offset from UTC.
ℹ️ Check
From the BIG-IP GUI: 1. System. 2. Platform. 3. Verify that "UTC" is configured for "Time Zone". From the BIG-IP Console, issue the following commands: tmsh list sys ntp timezone Note: This must return a value of "UTC". If the BIG-IP appliance is not configured for the UTC time zone, this is a finding.
✔️ Fix
From the BIG-IP GUI: 1. System. 2. Platform. 3. Set "UTC" for "Time Zone". 4. Click "Update". From the BIG-IP Console, issue the following commands: tmsh modify sys ntp timezone UTC tmsh save sys config