The DBMS must compare the internal system clocks on an organization-defined frequency with organization-defined authoritative time source.

Severity
Group ID
Group Title
Version
Rule ID
Date
STIG Version
mediumV-263622SRG-APP-000925SRG-APP-000925-DB-000330SV-263622r982511_rule2024-12-044
Description
Synchronization of internal system clocks with an authoritative source provides uniformity of time stamps for systems with multiple system clocks and systems connected over a network.
ℹ️ Check
Verify the DBMS is configured to compare the internal system clocks on an organization-defined frequency with organization-defined authoritative time source. If the DBMS is not configured to compare the internal system clocks on an organization-defined frequency with organization-defined authoritative time source, this is a finding.
✔️ Fix
Configure the DBMS to compare the internal system clocks on an organization-defined frequency with organization-defined authoritative time source.